Home / Genmitsu 3018-PROVer V2 / Repair

Why Does My Genmitsu 3018-PROVer V2 Fail to Home?

Exact model: Genmitsu 3018-PROVer V2

Safety: Remove cutting tools and disconnect both 24 V and USB before moving connectors or servicing axes.

A.

Start with the accessible checks

What this suggests: A homing failure must be separated by exact GRBL ALARM:6, :7, :8 or :9 or an obstruction: search not found, pull-off failure, or missing switch signal are not the same fault.

What to do

  1. Inspect V2 limit-switch positions and X/Y/Z-LIM plugs against the V2 board diagram, remove chips blocking switch travel and verify each switch changes its input state when pressed.
  2. Correct reversed or loose wiring and reposition a misaligned bracket.

Still not fixed? Continue to the next check.

↑ Back to the repair paths
B.

If the problem remains after the first checks

What to do

  1. Manually jog clear of a switch at a safe speed, then retest homing in clear space.
  2. Change homing direction or travel settings only against the actual V2 baseline and only if mechanically justified; never disable limit protection to hide an alarm.
↑ Back to the repair paths

Confirm the repair

Each axis finds its intended switch, backs off successfully and homing ends without further alarm.

Technical references

genmitsu.s3.us-east-1.amazonaws.com

docs.sainsmart.com

github.com