Home / VEVOR CIM-360T / Repair

Why Is My VEVOR CIM-360T Showing Error E1?

Exact model: VEVOR CIM-360T

Safety: Disconnect the relevant power source and isolate moving, hot or pressurized components before service.

A.

Start with the accessible checks

What this suggests: CIM-360T E1 identifies an open/disconnected temperature-probe circuit in its applicable manual, not proof of a failed compressor.

What to do

  1. Unplug and check the probe connector at the documented control location for loose fit, corrosion or broken conductors.

Still not fixed? Continue to the next check.

↑ Back to the repair paths
B.

If the problem remains after the first checks

What to do

  1. Have a qualified repairer reseat or renew a damaged terminal and, if the sensor itself is confirmed open, replace the matching factory probe, maintaining its original routing and sensing position.
  2. The published schematic identifies the circuit but does not establish a universal resistance-versus-temperature value for aftermarket sensors.
↑ Back to the repair paths

Confirm the repair

E1 clears and normal ice-making/harvest repeats without temperature code recurrence; verify correct model-specific replacement part before ordering.

Technical references

device.report

eur.vevor.com

device.report