Why Is My VEVOR CIM-360T Showing Error E1?
Exact model: VEVOR CIM-360T
Safety: Disconnect the relevant power source and isolate moving, hot or pressurized components before service.
A.
Start with the accessible checks
What this suggests: CIM-360T E1 identifies an open/disconnected temperature-probe circuit in its applicable manual, not proof of a failed compressor.
What to do
- Unplug and check the probe connector at the documented control location for loose fit, corrosion or broken conductors.
Still not fixed? Continue to the next check.
↑ Back to the repair pathsB.
If the problem remains after the first checks
What to do
- Have a qualified repairer reseat or renew a damaged terminal and, if the sensor itself is confirmed open, replace the matching factory probe, maintaining its original routing and sensing position.
- The published schematic identifies the circuit but does not establish a universal resistance-versus-temperature value for aftermarket sensors.
Confirm the repair
E1 clears and normal ice-making/harvest repeats without temperature code recurrence; verify correct model-specific replacement part before ordering.