Home / VEVOR CIM-360T / Repair

Why Is My VEVOR CIM-360T Making Ice That Is Too Thick?

Exact model: VEVOR CIM-360T

Safety: Disconnect the relevant power source and isolate moving, hot or pressurized components before service.

A.

Start with the accessible checks

What this suggests: Over-thick cubes are commonly a cycle-time setting issue; a slab left too thick can also stick to the evaporator and trigger E3.

What to do

  1. Use the CIM-360T panel's documented minus control to reduce ice thickness by one step, allowing the NEXT freezing cycle to finish before judging the result.
  2. Check incoming water distribution and evaporator cleanliness and clear scaled spray ports if necessary.

Still not fixed? Continue to the next check.

↑ Back to the repair paths
B.

If the problem remains after the first checks

What to do

  1. If ice is already stuck, perform the manufacturer's short manual De-icing operation instead of prying with metal tools.
  2. Note the manual's text has a plus/minus translation conflict; its illustrated operational instructions show minus reduces thickness.
↑ Back to the repair paths

Confirm the repair

Ice forms in a manageable slab and drops cleanly over two or more cycles without E3.

Technical references

device.report

eur.vevor.com

device.report