Why Is My VEVOR CIM-360T Making Ice That Is Too Thick?
Exact model: VEVOR CIM-360T
Safety: Disconnect the relevant power source and isolate moving, hot or pressurized components before service.
A.
Start with the accessible checks
What this suggests: Over-thick cubes are commonly a cycle-time setting issue; a slab left too thick can also stick to the evaporator and trigger E3.
What to do
- Use the CIM-360T panel's documented minus control to reduce ice thickness by one step, allowing the NEXT freezing cycle to finish before judging the result.
- Check incoming water distribution and evaporator cleanliness and clear scaled spray ports if necessary.
Still not fixed? Continue to the next check.
↑ Back to the repair pathsB.
If the problem remains after the first checks
What to do
- If ice is already stuck, perform the manufacturer's short manual De-icing operation instead of prying with metal tools.
- Note the manual's text has a plus/minus translation conflict; its illustrated operational instructions show minus reduces thickness.
Confirm the repair
Ice forms in a manageable slab and drops cleanly over two or more cycles without E3.